| Chemistry | LFP | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Usable energy | 55.29 kWhDC usable at 90% DOD, 0.3C, 25 C | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Nominal energy | 61.44 kWh | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Max. discharge power | 61.44 kWRated DC power; peak 125 A for 2 min | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Max. charge power | 61.44 kW'Rated DC Power 61.44'; nominal 100 A, recommended 50 A | download.axilogi.comDatasheet · read 28 Oct 2026 |
| C-rate | 0.5 CRecommended 50 A on 100 Ah = 0.5C; nominal 1C | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Round-trip efficiency | unavailable | Not published |
| Depth of discharge | 90 %'Recommend Depth of Discharge 90%' | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Cycle life | 6,000 cyclesConditions: 25+/-2C, 0.5C/0.5C, EOL70% >=6000 | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Warranty | 10 years'whichever reached first of warranty period or life cycle power' | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Warranty cycles | unavailable | Not published |
| Warranty throughput | unavailable | Not published |
| Capacity at end of warranty | unavailableEOL70% stated for cycle life, not explicitly as warranty threshold | Not published |
| Nominal voltage | 614.4 V | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Operating temperature | −30 to 45 °C; charging 0 to 55 °CCabinet operating -30~45 C (>45 derating); working temperature charge 0~55 / discharge -20~55 | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Dimensions (W × D × H) | 735 × 1,045 × 2,235 mm | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Weight | 1,010 kg | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Ingress protection | IP55 | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Integrated inverter (PCS) | No, battery only | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Scalability | Battery expansion to max 360 kWh (50 kW/360 kWh per inverter); up to 10 inverters AC-parallel (off-grid example 500 kW/600 kWh) | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Certifications | UN 38.3, CB, CE, CEC, IEC 62040 | download.axilogi.comDatasheet · read 28 Oct 2026 |
| Compatible inverters | unavailableDatasheet shows Deye 50 kW inverter application but names no model | Not published |